Sintex Permanent Magnets - Magnetic properties for samarium cobalt magnets

Magnetic properties for selected sintered samarium cobalt magnets:
(Click on the column headline in order to sort according to the chosen property)

 

NameTypeBr Typ [T]Br Min [T]bHc Typ [kA/m]bHc Min [kA/m]iHc Min [kA/m](BH) max Typ [KJ/m3]Min temp [°C]Max temp [°C]Temp. Coeff. Br [%/K]Temp. Coeff. Hc [%/K]
S1035-350SZ-200H Sm2Co171,0351,0207967481433207,0-100350-0,03-0,200
S1065-350SZ-220H Sm2Co171,0651,0507967561433223,0-100350-0,03-0,200
S810-250SC-120 SmCo50,8100,7805605601195130,0-100250-0,05-0,200
S830-250SC-130 SmCo50,8300,8005755751195140,0-100250-0,05-0,200
S850-250SC-140 SmCo50,8500,8206006001195145,0-100250-0,05-0,200
S880-250SP-145 SmCo50,8800,8506206201195151,0-100250-0,05-0,200
S930-250SP-160 SmCo50,9300,9007166521195175,0-100250-0,05-0,200
S985-350SZ-175H Sm2Co170,9850,9507326371433191,0-100350-0,03-0,200
SLTCLTc (YXG-22)0,9600,9406926681194175,0-100300-0.025 to +0.012**-0,200

 

** +0.005 (-50-20°C); +0.012 (20-100°C); +0.006 (100-200°C); -0.025 (200-300°C)

 

Please notice: The magnetic data shown here are the result of tests and calculations done on untreated magnet blocks. It may not be possible to directly attribute all the above given results to individual magnets. Before you use the information and results, you are therefore encouraged to seek personal assistance and advice from the magnet specialists at Sintex a/s.
 